Front panel IC-706: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
Line 19: | Line 19: | ||
* Second byte is probably Command number. | * Second byte is probably Command number. | ||
* Third byte is probably Sub command number. Mostly 0x00. | * Third byte is probably Sub command number. Mostly 0x00. | ||
* | * Folows Data area with variable length. | ||
* Last byte is End of message code ('''0xfd'''). | * Last byte is End of message code ('''0xfd'''). | ||
Revision as of 07:29, 18 February 2009
Cable pinout
Pin Signal Color Description 1 LRXD Yellow Data transfer from front panel to the radio. 2 LTXD Black Data transfer from radio to the front panel. 3 8V Blue DC power (8V) to the front panel. 4 AF Red Output audio to headphone jacket. 5 GND Shield Data, power, output audio and power control ground. 6 MIC White Microphone input. 7 MICE Green shield Microphone ground. 8 PWK White Power control (switch ON button). Active in low.
Switch on
Power switch on panel turns PWK signal to low (ground). Radio turns on supply voltage on pin 8V.
Communication
Both sides communicate at 19200 Baud, 8 bits, no parity, 1 stop bit. Protocol is similar to CI-V control. AFAIK it is not published so next informations are taked by reverse-engineering.
- Packet starts with Preamble code (0xfe).
- Second byte is probably Command number.
- Third byte is probably Sub command number. Mostly 0x00.
- Folows Data area with variable length.
- Last byte is End of message code (0xfd).
Commands
0x0b
Keepalive packet sent from panel to radio about every 100 ms. When no packet is received by radio in about 200 ms, it switches itself off. To provide reliable work over IP networks, this packet should be emulated.
0x60
Data to display on panel. Looks like bitmask controlling particular LCD segments/LEDs. No detailed description available at this time.